Brief Description | Priority |
A101004 Standard Foundations Repairs - Parging repairs Renewal | Urgent |
Auxiliary Equipment - Expansion Tank Renewal | Urgent |
Auxiliary Equipment - HVAC Pumps Renewal | Urgent |
Auxiliary Equipment - Heat Exchanger - Shell & Tube Renewal | Urgent |
B3010 Roof Coverings - EPDM/Inverted -Section B1,D Renewal | Urgent |
Hot Water Boilers - Boiler #1, #2 and #3 Renewal | Urgent |
Hot Water Boilers - DHW Boiler Renewal | Urgent |
Air Distribution, Heating & Cooling - Duct System Renewal | High |
Air Handling Units - All Renewal | High |
Auxiliary Equipment - Chemical Feed System Renewal | High |
Auxiliary Equipment - Stack & Breaching Renewal | High |
B201011 Exterior Walls - Joint Sealant Renewal | High |
B201014 Exterior Walls - Masonry Re-pointing Renewal | High |
B203008 Exterior Doors - Hardware Renewal | High |
B3010 Roof Coverings - Metal Roof Assembly System - Sections A, BD1, BD2, BD3, BD4, C1, CE1, CE2, CE3, D, DG1, DG2 Renewal | High |
C103016 Fittings - Bleachers Renewal | High |
C302003 Floor Finishes - Wood - Stage Renewal | High |
C302004 Floor Finishes - Vinyl Tile Renewal | High |
Controls & Instrumentation - BAS Renewal | High |
Controls and Instrumentation - Pneumatic Renewal | High |
Cooling Generating Systems - Cooling Condenser - Office Renewal | High |
Cooling Generating Systems - Window AC Renewal | High |
Distribution Systems - Exhaust Systems - Axial Renewal | High |
Domestic Water Distribution - DHW Storage Tank Renewal | High |
Domestic Water Distribution - Eyewash Stations Renewal | High |
Domestic Water Distribution - Plumbing Piping System Renewal | High |
Electrical Service and Distribution - Secondary Transformers Renewal | High |
Exterior Doors - Hollow Metal Renewal | High |
Exterior Windows - Original Renewal | High |
Floor Finishes - Carpet Renewal | High |
Floor Finishes - Sheet Vinyl Renewal | High |
G204001 Fencing and Gates - Chain Link Fence Renewal | High |
Gas Supply System - Piping Renewal | High |
Main Switchboards - Main Disconnect & Main Distribution Panel Renewal | High |
Perimeter Heating - Terminal Units Renewal | High |
Plumbing Fixtures - Bradley Basins Renewal | High |
Plumbing Fixtures - Lavatories Renewal | High |
Plumbing Fixtures - Urinals Renewal | High |
Plumbing Fixtures - Water Closets Renewal | High |
Plumbing Fixtures - Water Coolers Renewal | High |
Wall Finishes - Painted - Drywall and Concrete Block Renewal | High |
Branch Wiring Renewal | Medium |
C1010 Partitions Renewal | Medium |
C101003 Partitions - Moveable - Foldable Partition (GYM) - New Renewal | Medium |
C102007 Interior Doors - Hardware Renewal | Medium |
C103001 Fittings - Washroom Partitions - Water Closet Renewal | Medium |
C103002 Fittings - Washroom Accessories Renewal | Medium |
C103010 Fittings - Millwork - Laboratories Renewal | Medium |
C302001 Floor Finishes - Ceramic Renewal | Medium |
Fire Protection Specialties - Kitchen Suppresion Systems Renewal | Medium |
Fittings - Millwork Renewal | Medium |
Interior Doors - Wood & Metal Renewal | Medium |
Domestic Water Distribution - DHW Tanks Renewal | Low |
Fencing & Gates - Hollow Steel Control Gate Renewal | Low |
Fittings - Lockers Not Built - In Renewal | Low |
Fittings - Lockers Renewal | Low |
Fittings - Window Coverings - Drapes Renewal | Low |
Floor Finishes - Gym 1,2,3 - Hardwood Renewal | Low |
Landscaping Renewal | Low |
Pedestrian Paving - Asphalt Renewal | Low |
Pedestrian Paving - Concrete Renewal | Low |
Playing Fields - Unpaved - Football Field Renewal | Low |
Playing Fields - Unpaved - Track Renewal | Low |
Signage - Wall Mounted & Freestanding Renewal | Low |